Indications

The implants of the Activ Ankle range are intended for the fixation of fractures, osteotomies and pseudarthroses of the distal and the diaphyseal fibula, for the fixation of fractures of the medial malleolus and for the syndesmotic repair in adults.

Technical features

Distal & Diaphyseal Fibula 

  • 3 types of distal plates designed for different kinds of fractures, skins, bone quality and surgical techniques
  • 2 surgical approaches: lateral and postero-lateral
  • Optimal design reducing the risk of soft tissue irritation thanks to the rounded distal edges
  • Dualtec System 2 technology: polyaxial holes allowing +/-10° angulation (20° cone)

Distal Tibia Plate 

  • 2 types of plates: hook and standard
  • 1 short plate using a smaller incision
  • Optimal design reducing the risk of soft tissue irritation thanks to the rounded distal edges
  • Dualtec System 2 and 3 technology: polyaxial holes allowing +/-10° angulation (20° cone)

 

Implants

Distal & Diaphyseal Fibula  

  • 3 types of distal plates:
    - lateral standard in 5 sizes (length 75 to 187 mm) available in right and left versions
    - lateral narrow in 2 sizes (length 76 to 102 mm)
    - postero-lateral (73 mm) available in right and left versions
  • 1 symmetrical diaphyseal plate (65 mm) - Diaphyseal fixation: Ø3.5 mm locking and non-locking cortical screws, length 10 to 24 mm (2mm increment) 
  • Epiphyseal fixation: Ø2.8 mm locking and non-locking screws, length 10 to 24 mm (2mm increment)
  • Fixation in case of syndesmosis injury: Ø3.5 mm non-locking cortical screw and Ø4.0 mm lag screw, length 40 to 70 mm (5mm increment)

 Distal Tibia Plate 

  • 2 types of distal plates :
    - standard in 2 sizes (0 and 1) with 2 upward screws for rigid fixation 
    - hook in 1 size with 1 upward screw for a low profile
  • Implant adapted to vertical and transverse fractures
  • Fixation : 
    - Ø2.8 mm locking screws, 10 to 24 mm (2mm increment)
    - Ø2.8 mm sterile locking screws, 30 to 60 mm (2mm increment)
    - Ø2.8 mm sterile cortical screws, 10 to 60 mm (2mm increment)

Surgical techniques: final results

Distal & Diaphyseal Fibula : Lateral approach

MONTAGE LATERAL STANDARD

Lateral standard plate - Size 2

Further information

Distal & Diaphyseal Fibula : Lateral approach

MONTAGE LATERAL NARROW

Lateral narrow plate - Size 2

Further information

Distal & Diaphyseal Fibula : Postero-lateral approach

MONTAGE POSTEROLATERAL

Postero-lateral plate - Size 1

Further information

References

Lateral standard plates

REF_LATERALE_STANDARD

Lateral narrow plates

REF_LATERALE_NARROW

Postero-lateral plates

REF_POSTEROLATERALE