The implants of the Xpert Ankle range are intended for the fixation of fractures, osteotomies and pseudarthroses of the distal and the diaphyseal fibula, the distal tibia and for the syndesmotic repair in adults
Ankle fractures account for 10%1 of all fractures in adults. For this reason, Newclip Technics developed the Xpert Ankle range, which offers a comprehensive solution for the treatment of injuries to the medial, lateral, and posterior malleolus, as well as diaphyseal fibula fractures. Owing to their design and in-depth understanding of fracture typologies, these plates enable management of a broad spectrum of fracture patterns.
A 360° approach to the management of trimalleolar fractures.
Isolated fibula fractures account for 65–70%2 of malleolar complex injuries. For this reason, Xpert Ankle offers 5 plate sizes for fixation of distal fibula fractures via a lateral approach. The distal head provides a broad range of fixation options to address complex fractures.
In cases of associated syndesmotic disruption, present in 10%3 of ankle fractures, a syndesmosis screw or double-button fixation device can be placed in the dedicated holes.*
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
Available as a single-use kit – INITIAL A Xpert
Xpert Ankle also offers 3 sizes of straight lateral plates for fixation of distal fibula fractures via a lateral approach. The low-profile design and reduced width allow management of simple fractures.
In cases of associated syndesmotic disruption, a syndesmosis screw or double-button fixation device can be placed in the dedicated holes.*
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
Available as a single-use kit – INITIAL A Xpert
Posterolateral fragments are present in 88%4 of isolated fibula fractures. For this reason, Xpert Ankle additionally offers 3 plate sizes for fixation of distal fibula fractures via a posterior or posterolateral approach.
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
Xpert Ankle offers a straight plate that can be applied to both the fibula and the distal tibia, available in 5 sizes.
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
Available as a single-use kit – INITIAL A Xpert
In line with our 360° approach, posterior malleolus fractures can account for up to 44% of ankle fractures. 5
Xpert Ankle therefore offers 2 sizes of posterolateral plates for fixation of posterior malleolus fractures. If required, this plate can be used in combination with the posteromedial plate.
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
In line with our 360° approach, posterior malleolus fractures can account for up to 44% of ankle fractures.5
Xpert Ankle offers 2 sizes of posteromedial plates for fixation of posterior malleolus fractures. If required, this plate can be used in combination with the posterolateral plate.
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
In line with our 360° approach, posterior malleolus fractures can account for up to 44% of ankle fractures.5
Xpert Ankle additionally offers a fully posterior plate, available in 2 sizes, for fixation of posterior malleolus fractures.
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, Ø2.8 mm or Ø3.5 mm screws, locking or non-locking.
The Xpert Ankle plate range includes two standard plates and one hook plate, dedicated to the fixation of distal medial malleolus fractures, addressing different surgical philosophies and anatomical constraints of the target region.
Each holes is lockable, offers polyaxial orientation, and can accommodate, depending on surgical requirements, locking or non-locking Ø2.8 mm screws.
Fragment fixation with a Ø4.0 mm cannulated or non-cannulated screw is also possible.
- Locking screw Ø2.8 mm (1)
- Non-locking screw Ø2.8 mm (2)
- Locking screw Ø3.5 mm (3)
- Non-locking screw Ø3.5 mm (4)
- Non-locking screw Ø3.5 mm (4)
- Lag screw Ø4.0 mm (5)
- Cannulated compressive screw Ø4.0 mm (6)
1- Vieira Cardoso, D., Dubois-Ferrière, V., Gamulin, A. et al. Operatively treated ankle fractures in Switzerland, 2002–2012: epidemiology and associations between baseline characteristics and fracture types. BMC Musculoskelet Disord 22, 266 (2021). https://doi.org/10.1186/s12891-021-04144-5
2- Olías-López B, Boluda-Mengod J, Rendón-Díaz D, Ojeda-Jiménez J, Martín-Herrero A, Morales-Mata E, Herrera-Pérez M. [Translated article] Fractures of the peroneal malleolus: Current concepts. Rev Esp Cir Ortop Traumatol. 2024 Sep-Oct;68(5):T502-T512. English, Spanish. doi: 10.1016/j.recot.2024.07.014. Epub 2024 Jul 23. PMID: 39053809
3- W.J. van Zuuren, T. Schepers, A. Beumer, I. Sierevelt, A. van Noort, M.P.J. van den Bekerom,Acute syndesmotic instability in ankle fractures: A review,Foot and Ankle Surgery,Volume 23, Issue 3,2017,Pages 135-141,ISSN 1268-7731,https://doi.org/10.1016/j.fas.2016.04.001.
4- A New Three-Dimensional Classification of Proximal Tibiofibular Fractures: A Multicenter Study, Li-ping Wu MD, Hermann O Mayr MD, Qin Cai MS, Yuan-qiao Huan MS, Xiao-hua Zhu MS, Yuan-zhuang Chen BS, Yi-ping Tang MS, Xin-yu Huang BS, First published: 20 October 2021 https://doi.org/10.1111/os.13161
5- https://www.bofas.org.uk/hyperbook/trauma/ankle-fractures/posterior-malleolus
Key features of the Xpert Ankle Range.
- A comprehensive range enabling 360° management of ankle fractures, with a solution specifically designed to provide exhaustive coverage of posterior fractures
- Plates with a low-profile, anatomical design with a versatile locking system
- Polyaxial locking fixation available on all holes
- Non-locking Ø3.5 mm screws dedicated to syndesmosis stabilization
- Lag screws Ø4.0 mm designed for fixation of distal medial malleolus fractures
- Implants available in three configurations: sterile, non-sterile, or within a single-use kit* (INITIAL A Xpert)
* Only for lateral standard, straight lateral and straight plates
Our INITIAL solution for the ankle.