Activmotion S (US) Your solution to align the knee and preserve the joint
Our philosophy : Knee alignment
Opening wedge tibial plates
Opening wedge tibial plates with ligamentoplasty
Lateral closing HTO plates
Medial closing HTO plates
Slope change tibial plateau
Lateral opening DFO plates
Medial closing DFO plates
Femoral closing and derotation plates
- Treatment of varus deformities
- Medial opening osteotomy of the proximal tibia
- Valgus correction osteotomies
- Anteromedial position
Size 1 allows allows performing monoplanar osteotomies with up to 12 mm of correction.
Size 2 is particularly suitable for biplanar cuts
- Treatment of varus deformities
- Medial opening osteotomy of the proximal tibia
- Valgus correction osteotomies, combined with ligamentoplasty of the knee
- Anteromedial position
- Inverted form to create a ligamentoplasty tunnel
- Polyaxial locking hole located in the proximal part to avoid the tunnel and not damage the ligament graft
This anatomical place is also available with a space directly on the plate to position a non-metallic or titanium rectangular suture button (3.8 x 12 mm).
- Available in two sizes
- Treatment of varus deformities
- Lateral closing osteotomy of the proximal tibia
- Valgus correction osteotomies
- Specially suitable for biplanar and/or oblique cuts
- Compressive ramp oblong hole to optimize the osteotomy compression
For size 2, the presence of two cross screws participates in the compression and stabilisation of the osteotomy.
- Treatment of valgus deformities
- Medial closing osteotomy of the proximal tibia
- Varus correction osteotomies
- Compressive ramp oblong hole to optimize the osteotomy compression
Available in 2 sizes.
Two designs adapted to the different techniques :
- Small plate for the supra and trans-tubercle techniques,
- Longer plate for the infra-tubercle technique.
1 central polyaxial screw to avoid the ACL tunnel and any conflict with the osteotomy cut.
Screws orientation studied to support to support both the medial and lateral plateau.
Ramp oblong hole to compress the osteotomy.
- Treatment of valgus deformities
- Lateral opening osteotomy of the distal femur
- Varus correction osteotomies
- Its two off-set screws on either side of osteotomy gap allow improving the mechanical characteristics of the assembly, and preventing loss of angular correction.
- Its polyaxial locking screw, located in the distal section, allows avoiding the intercondylar notch, if necessary.
- Treatment of valgus deformities
- Medial closing osteotomy of the distal femur
- Varus correction osteotomies
- With an oblong ramp compression hole that optimises the compression of the osteotomy
- Its two off-set screws above osteotomy gap allow improving the mechanical characteristics of the assembly, and preventing loss of angular correction.
- Its polyaxial locking screw, located in the distal section, allows avoiding the intercondylar notch, if necessary.
Dedicated to femoral closing osteotomies and femoral derotation.
A hinge screw integrated directly through the plate and extending to the opposite cortex to stabilize the osteotomy.
With an oblong ramp compression hole that optimises the compression of the osteotomy
Its two off-set screws above osteotomy gap allow improving the mechanical characteristics of the assembly, and preventing loss of angular correction.
Its polyaxial locking screw, located in the distal section, allows avoiding the intercondylar notch, if necessary.
Compatible with our patient specific cutting guides
The One Solution