Activmotion S (US) Your solution to align the ankle and preserve the joint

Our philosophy : Knee alignment
Opening wedge tibial plates
Opening wedge tibial plates with ligamentoplasty
Lateral closing HTO plates
Medial closing HTO plates
Lateral opening DFO plates
Medial closing DFO plates
- Treatment of varus deformities
- Medial opening osteotomy of the proximal tibia
- Valgus correction osteotomies
- Anteromedial position
Size 1 allows allows performing monoplanar osteotomies with up to 12 mm of correction.
Size 2 is particularly suitable for biplanar cuts and corrections greater than 12 mm.
- Treatment of varus deformities
- Medial opening osteotomy of the proximal tibia
- Valgus correction osteotomies, combined with ligamentoplasty of the knee
- Anteromedial position
- Inverted form to create a ligamentoplasty tunnel
- Polyaxial locking hole located in the proximal part to avoid the tunnel and not damage the ligament graft
This anatomical place is also available with a space directly on the plate to position a non-metallic or titanium rectangular suture button (3.8 x 12 mm).
- Available in two sizes
- Treatment of valgus deformities
- Medial closing osteotomy of the proximal tibia
- Varus correction osteotomies
- Anteromedial position
Oblong ramp compression hole to optimise the osteotomy compression.
- Treatment of valgus deformities
- Medial closing osteotomy of the proximal tibia
- Varus correction osteotomies
- With an oblong ramp compression hole that optimises the compression of the osteotomy.
- Specially suitable for biplanar and/or oblique cuts
Available in 2 sizes.
For size 2, the presence of two cross screws participates in the compression and stabilisation of the osteotomy.
- Treatment of valgus deformities
- Lateral opening osteotomy of the distal femur
- Varus correction osteotomies
- Its two off-set screws on either side of osteotomy gap allow improving the mechanical characteristics of the assembly, and preventing loss of angular correction.
- Its polyaxial locking screw, located in the distal section, allows avoiding the intercondylar notch, if necessary.
- Treatment of valgus deformities
- Medial closing osteotomy of the distal femur
- Varus correction osteotomies
- With an oblong ramp compression hole that optimises the compression of the osteotomy
- Its two off-set screws above osteotomy gap allow improving the mechanical characteristics of the assembly, and preventing loss of angular correction.
- Its polyaxial locking screw, located in the distal section, allows avoiding the intercondylar notch, if necessary.